Home & Garden

Christmas Lights: The LED String Runs on a Tenth of the Power

A 100-bulb incandescent string draws about 40 watts; an LED about 4. Here is what that costs over December at 2026-27 default offer rates, and the safety rule.

Published

on

The old bulbs are the story. A 100-bulb incandescent string draws about 40 watts. The LED equivalent draws 2 to 4. Same look, roughly a tenth of the power. That is the whole case for swapping, and it does not depend on the brand or the shop.

Here is the verdict, and it does not change. Buy LED, put the display on a timer, keep every set outdoor-rated, and never join more sets end to end than the label allows. The rest of this piece is the arithmetic behind that, because the cost figures online disagree by a factor of a hundred.

Work out what your lights cost to run

Enter the number of strings, the watts on each string's label, the hours and nights you run them, and the rate from your bill. The result updates as you type.

Enter the strings, the watts on the label, the hours and nights you run them, and the rate from your bill, and the season's cost appears here.

Enter the strings, watts, hours, nights and rate to see the season's cost.

The watts are on the label on the set or the plug. Count every string you plan to run.

The article's table sets out the rates it uses. Your own rate is on your bill. This only does the arithmetic.

Uses only the numbers you type. It does not include supply charges, solar export, time-of-use periods or standby load, and it does not know your tariff or your wattage. Check your bill and the label.

Why the quotes disagree

One guide says a few dollars. Another says about $14 a day. Both can be right, because they are describing different bulbs. Count does not set the load. The bulb does.

A mini incandescent bulb draws about 0.4 watts. Seven hundred of them is 280 watts. A large C9 incandescent bulb draws 5 to 7 watts. Seven hundred of those is 3.5 to 4.9 kilowatts, about twelve to eighteen times the load for the same count. Put either through the same hours and the same tariff and the bills separate the same way.

The $14 a day figure holds for a large C9 display run for long hours on a high tariff. It does not hold when applied to a mini display. A quote that gives a count without a bulb type cannot be checked, and that is the mistake.

Run the figure through the season. Fourteen dollars a day for 30 days is $420. At the Ausgrid rate, that is about 1,267 kilowatt hours, which over 180 hours is a load of about 7 kilowatts. That is a very large C9 display. A mini display is not in that territory, and a quote that uses the C9 number for a mini set is the source of the confusion.

The other two variables are hours and tariff. Six hours a night for 30 nights is 180 hours, which is the season used here. The rates are the AER’s 2026-27 residential flat-rate default offer caps, GST inclusive, in force from 1 July 2026. The table runs three displays through that season on three networks.

Display Load kWh over 180 hours Ausgrid 33.14 cents Energex 27.97 cents SA Power Networks 41.91 cents
1,000 mini incandescent 400 W 72 $23.86 $20.14 $30.18
1,000 mini LED 40 W 7.2 $2.39 $2.01 $3.02
700 large C9 incandescent at 5 W 3,500 W 630 $208.76 $176.24 $264.03

The rates are rounded in the headings; the dollar figures use the published rates. The point of the table is the shape, not the cent. A 1,000-bulb mini display costs tens of dollars for the season. A 700-bulb C9 display costs hundreds. The count is not the load. The bulb is.

Hours are the multiplier that gets left out. Eight hours a night for 30 nights is 240 hours, a third more than the table’s season. The same 1,000-bulb incandescent display would be 96 kilowatt hours, $31.81 on Ausgrid, and the LED version 9.6 kilowatt hours, $3.18. The tariff and the bulb set the rate; the hours set how long you pay it.

The official number and the string number

The Energy Rating website says a good LED uses around 75 per cent less electricity than a halogen and lasts 5 to 15 times longer. The string on the house can do better than that. A 100-bulb incandescent set at 40 watts against an LED set at 4 watts is a 90 per cent reduction.

Both numbers are true, and they measure different things. The 75 per cent is the government’s like-for-like lighting comparison: an LED globe against a halogen globe of similar output. The 90 per cent is a set-to-set comparison at the same bulb count: an incandescent string against an LED string. Neither figure is the number for a particular display. That number is on the label and on the bill.

The common claim of “up to 90 per cent less” is the same comparison at the top of the LED range. At 2 watts per 100 bulbs, the reduction against a 40-watt incandescent set is 95 per cent. At 4 watts, it is 90. The direction is the same; the exact number depends on the set in your hand.

The longevity claim matters to the payback. A set that lasts 5 to 15 times longer needs replacing less often, so the purchase price spreads over more seasons. The running-cost case does not need that argument. The total-cost case does.

The efficiency claim has limits. A cheap LED set can dim or fail early, which is a quality problem rather than a running-cost one. And the saving assumes the same number of strings before and after. Buy more sets because LEDs are cheap and the bill can climb while the efficiency improves.

The general lighting figure compares LED with halogen, a different baseline from the small incandescent bulbs in a Christmas set. The two comparisons start from different lamps, which is why the percentages differ. Neither is wrong, and neither is the number on your bill.

The 75 is a general lighting figure. The 90 is the string. Both hold.

The arithmetic

The formula is the one every running-cost question uses: watts times hours divided by 1,000 gives kilowatt hours; kilowatt hours times cents per kilowatt hour divided by 100 gives dollars. The same method sits behind our air fryer running-cost comparison; the appliance changes, the arithmetic does not.

At 180 hours for 1,000 bulbs: 400 watts is 72 kilowatt hours, which costs $23.86 on the Ausgrid default offer and $30.18 in South Australia. The LED version at 40 watts is 7.2 kilowatt hours, $2.39 and $3.02. The saving is $21.47 on the Ausgrid network and $27.16 on the SA Power Networks rate.

A single 100-bulb string is the small end. 7.2 kilowatt hours for the season, $2.39 on Ausgrid. The LED version is 0.72 kilowatt hours, 24 cents. A real saving, and a small one. This is why the small-display point deserves stating: if the display is one string, the running cost was never the problem.

The middle of the range is where the disagreement matters. Seven hundred mini incandescent bulbs at 0.4 watts draw 280 watts, 50.4 kilowatt hours, $16.70 on Ausgrid for the season. The same 700 bulbs in large C9 at 7 watts draw 4.9 kilowatts, 882 kilowatt hours, $292.27. Same count, same season, a difference of $275 before the cost of the LED replacement.

The same 700 bulbs in mini LED at 0.04 watts each draw 28 watts, 5.04 kilowatt hours, $1.67 on Ausgrid. That is the full range: $1.67 to $292.27 for the same count, depending on the bulb and the set.

A 700-bulb C9 display at 5 watts is the other end. 3.5 kilowatts, 630 kilowatt hours, $208.76 on Ausgrid for the season, before the supply charge. That is the display the online quotes describe when they talk about dollars a day. The wattage is on the label, and the label is the number to check first.

Every figure here is energy only. The daily supply charge on the same default offer is separate, and it applies whether the display runs or not. The energy line is the one the swapping decision changes.

The payback

The payback is honest, which is more than most of the marketing manages. A 500-LED string was listed at about $20 at the major retailers in early November. Two strings, about $40, replace 1,000 bulbs. The saving at the Ausgrid rate is $21.47 a season. Forty divided by 21.47 is 1.86, so the honest number is about two seasons.

One season holds on a large C9 display, where the seasonal saving is $200 or more, so even a replacement set with a real premium clears its cost in the first year. The payback also assumes full retail and the NSW default offer. A cheaper LED set shortens it. A smaller display stretches it.

The calculation uses the full LED purchase price, not the difference between an LED set and an incandescent one. If the old set is already owned, that is the right comparison. If both are being bought new, the LED premium is smaller and the payback is faster.

The other side has a fair point. For one small string, the saving is a couple of dollars a season, and the purchase price takes years to repay. In that case the stronger reasons to swap are safety, longevity and the load on the circuit, not the bill. The running-cost argument is for the display, not for the single strand.

The timer

The cheapest control is a timer. Six hours a night against 10 saves 120 hours over the season. On a 400-watt display that is 48 kilowatt hours, about $16 on the Ausgrid rate. A $10 timer pays for itself in the first season and removes the nightly decision.

Ten hours a night is the other habit: on at dusk, off when the house goes to bed. The extra four hours are the ones nobody watches. They are also the ones the timer removes without anyone having to remember.

A plug-in timer sits between the set and the socket. If it is going outdoors, it needs an outdoor rating. That is the whole installation.

Energy Safe Victoria’s advice is to turn the lights off before bed or before leaving the house. A timer does that without anyone remembering. It also takes the load off the circuit overnight, which matters more than the bill on an old display.

The circuit has its own limit, and it is not the timer’s. Our piece on the load an induction cooktop puts on a circuit explains how household circuits are rated. The same logic applies to a daisy chain of Christmas sets.

The safety rules

The safety rules are short, and they are not optional. Energy Safe Victoria’s advice, plus the label on the set, covers most of it.

  • Outdoor sets need an IP rating of at least IP23, and only sets intended for outdoors belong outdoors.
  • Look for the RCM mark on new sets, and check the EESS registration on the national register. Insulated pins have been required on appliances sold after 2006.
  • Inspect old sets before they go up: cracked insulation, exposed wire, broken lampholders, damaged plugs. Replace them, do not tape them.
  • No double adaptors, no piggy-backing plugs, no powerboard plugged into a powerboard. High-powered lamps can overload a circuit.
  • Do not exceed the connection limit on the label. It is a current limit, not a suggestion.
  • LED, extra-low-voltage (5V, 12V or 24V) or solar sets are the safest options. No lights over pools.
  • Turn them off before bed or before leaving.

The IP rating and the compliance marks are worth knowing before the set goes up. The IP rating is a weather rating, not a waterproof one: IP23 keeps out fingers and sprayed water, not immersion, so an outdoor set still stays out of reach of a pool. The RCM is the regulatory compliance mark, and EESS registration puts the set on the national electrical equipment register. The RCM is visible on the product or its packaging; the EESS entry is checked on the register.

The connection limit and the indoor set deserve a sentence each. The connection limit is the one people ignore, because the spare socket is there and the label is small. Owners of large displays online report tripping a circuit breaker with about ten strands of C9; the label’s limit is the one that applies. And an indoor set outside is not a shortcut. The insulation and the plug are not made for weather.

Swap the string, set the timer

Swap the string, set the timer, keep it outdoor-rated, and respect the label. That is the whole advice, and it holds whether the display is one strand or seven hundred bulbs.

What to skip: a large incandescent C9 display bought new, a daisy chain of powerboards, an indoor set on the eaves, and any plan that depends on remembering to turn it off. The display is allowed to cost something. It is not allowed to be a surprise.

The display is the point. A dark house saves the most and gives the street nothing. The argument is for cheaper bulbs and a smaller bill, not for dark houses.

The rest of the Christmas spend works the same way. Our piece on the real or artificial Christmas tree runs the same comparison for the tree: what it costs to buy, what it costs to run, and which one wins over the years. The lights are the easy part.

Sources: Switch and save, Energy Rating, Australian Government (https://www.energyrating.gov.au/consumer-information/products/lighting/switch-and-save); Default market offer prices 2026-27: final determination, Australian Energy Regulator (https://www.aer.gov.au/system/files/2026-05/AER%20-%20Final%20determination%20-%20Default%20market%20offer%202026%E2%80%9327.pdf); Christmas light safety, Energy Safe Victoria (https://www.energysafe.vic.gov.au/community-safety/energy-safety-guides/home-safety/christmas-light-safety); Christmas lights running costs: LED vs solar vs battery, Christmas World (https://www.christmasworld.com.au/blogs/guides/christmas-lights-running-costs)

Leave a Reply

Your email address will not be published. Required fields are marked *

Trending

Exit mobile version